IDEV Presents Consistent Evidence Validating the Mimetic Design of SUPERA Stent

MIAMI and WEBSTER, Texas, Oct. 22, 2012 /PRNewswire/ -- IDEV Technologies, Inc. (IDEV) today announced the presentation of consistent positive clinical outcomes of the SUPERA® Peripheral Stent System from its SUPERB pivotal U.S. clinical trial and SUPERA 500 long-term registry conducted in Germany.IDEV's data confirms a robust and consistent growing body of clinical evidence for SUPERA's highly differentiated, disruptive and proprietary stent design. The presentation was given today by SUPERB co-primary investigator Lawrence Garcia, M.D., Chief, Interventional Cardiology and Vascular Interventions at Steward St. Elizabeth's Medical Center at the 24th Annual Transcatheter Cardiovascular Therapeutics (TCT) scientific symposium, sponsored by the Cardiovascular Research Foundation.

SUPERB, a Food and Drug Administration (FDA) Investigational Device Exemption (IDE) trial, demonstrated the highest patency rates in peripheral IDE stent trials for superficial femoral or proximal popliteal artery disease that have been publically reported (86% based on survival analysis at 12 months). In addition, it is the first femoral-popliteal artery IDE trial to record zero stent fractures for bare or drug coated nitinol-based technologies.

The SUPERA 500 Registry included ahighly challenging real world patient population of 495 patients, 750 stents, and a mean stent length of nearly 13 cm, with 45% and 41%of the SUPERA stentsplaced in the distal SFA and proximal popliteal artery, respectively.The one and two-year patency rates were 84.1% and 73%, respectively, as measured by duplex ultrasound.Consistent withthe SUPERB trial, there were zero reported stent fractures at one year and also at two years in the SUPERA 500 registry.

"Results showing SUPERA's ability to consistently achieve a durable high patency rate with zero stent fractures even in longer lesion lengths and in later years of follow-up are quite impressive," said Dr. Garcia."When compared to standard nitinol stents, covered stent designs and drug-eluting stent technologies, the outcomes achieved with the SUPERA stent suggest that SUPERA may represent a new standard of stent design for treating superficial femoral artery (SFA) disease."

The SUPERA stent's interwoven nitinol wire technology platform offers significantly improved radial strength, flexibility and kink resistance,and is designed to adapt to the motion of the vascular anatomy.The SFA and popliteal arteries are exposed to significant mechanical stress with bending and rotation of the knee, and represent a harsh environment for any endovascular device. An ideal stent for use in these areas should offer a great range of motion without interrupting the anatomical function of the arteries.

"SUPERA is first in a new class of stents, vascular mimetic stents, engineered to mimic the vascular anatomy for optimal flexibility and strength," said Christopher Owens, President and CEO of IDEV. "The SUPERB and SUPERA 500 results validate the SUPERA design as well as data previously reported in numerous single-site registries and retrospective studies. With this data, and additional studies soon to be released, we are building one of the most robust bodies of evidence in PAD. We will continue to develop the SUPERA stent for other markets, lesion types and locations."

Data from the SUPERB trial will be utilized for IDEV's premarket approval (PMA) application with the FDA, which the Company anticipates filing in the fourth quarter of 2012.

About SUPERB
The SUPERB Trial (Comparison of the SUPERA PERipheral System to a Performance Goal Derived from Balloon Angioplasty Clinical Trials in the Superficial Femoral Artery) is an FDA approved IDE trial to evaluate SUPERA in treating patients with obstructive SFA and proximal popliteal artery disease.

SUPERB data analysis was performed independently and validated by the Harvard Clinical Research Institute (HCRI).

About the SUPERA Stent
The SUPERA stent is currently indicated in the United States for the palliative treatment of biliary strictures produced by malignant neoplasms and in multiple other countries for the treatment of biliary strictures produced by malignant neoplasms and for peripheral vascular use following failed percutaneous transluminal angioplasty (PTA).

About IDEV Technologies, Inc.
IDEV is a developer of endovascular technologies designed to protect and restore anatomical function. The Company is focused on redefining the endovascular treatment paradigm by providing physicians and patients with a new standard of technologies that deliver clinical excellence. For more information, please visit www.idevmd.com.

SOURCE IDEV Technologies, Inc.

Großer Insider-Report 2024 von Dr. Dennis Riedl
Wenn Insider handeln, sollten Sie aufmerksam werden. In diesem kostenlosen Report erfahren Sie, welche Aktien Sie im Moment im Blick behalten und von welchen Sie lieber die Finger lassen sollten.
Hier klicken
© 2012 PR Newswire
Werbehinweise: Die Billigung des Basisprospekts durch die BaFin ist nicht als ihre Befürwortung der angebotenen Wertpapiere zu verstehen. Wir empfehlen Interessenten und potenziellen Anlegern den Basisprospekt und die Endgültigen Bedingungen zu lesen, bevor sie eine Anlageentscheidung treffen, um sich möglichst umfassend zu informieren, insbesondere über die potenziellen Risiken und Chancen des Wertpapiers. Sie sind im Begriff, ein Produkt zu erwerben, das nicht einfach ist und schwer zu verstehen sein kann.