Kanazawa University research: Faster and less-invasive atomic force microscopy for visualizing biomolecular systems

KANAZAWA, Japan, March 19, 2021 /PRNewswire/ -- Researchers at Kanazawa University report in Review of Scientific Instruments a newly developed atomic force microscopy approach for imaging biological samples and processes. The method offers higher frame rates and less disturbance of samples.

High-speed atomic force microscopy (HS-AFM) is an imaging technique that can be used for visualizing biological processes, for example the activity of proteins. Nowadays, typical HS-AFM frame rates are as high as 12 frames per second. In order to improve the capabilities of the method, so that it can be applied to an ever expanding range of biological samples, better video rates are needed, though. Moreover, faster recording times imply less interaction between the sample and the probe - a tip scanning the sample's surface - making the imaging procedure less invasive. Now, Shingo Fukuda and Toshio Ando from Nano Life Science Institute (WPI-NanoLSI), Kanazawa University have developed an alternative HS-AFM approach to increase the frame rate up to 30 frames per second.

An AFM image is generated by laterally moving a tip around just above a sample's surface. During this xy-scanning motion, the tip's position in the direction perpendicular to the xy-plane (the z-coordinate) will follow the sample's height profile. The variation of the z-coordinate of the tip then produces a height map - the image of the sample.

Fukuda and Ando worked on HS-AFM in the so-called amplitude-modulation mode. The tip is then made to oscillate with a set amplitude. While scanning a surface, the oscillation amplitude will change because of height variations in the sample's structure. To get back to the original amplitude, a correction to the tip-sample distance needs to be made. How large the correction needs to be is related to the sample's surface topology, and is dictated by the so-called feedback control error of the setup. The scientists noted that the feedback control error is different when the tip moves in opposite directions, called tracing and retracing. This difference is ultimately due to the different physical forces at play when the tip is 'pulled' (tracing) and when it is 'pushed' (retracing).

Based on their insights into the physics of the tracing and retracing processes, Fukuda and Ando developed an imaging regime that bypasses retracing. This then needs to be properly accounted for in the controlling algorithm. The researchers tested their only-trace-imaging mode on actin filament samples. (Actin is a protein very common in cells.) The imaging was not only faster, but also less invasive - the filaments broke much less frequently . They also recorded polymerization processes (through protein-protein interactions); again, the method was found to be faster and less disturbing compared to the standard AFM tracing-retracing operation.

The scientists are confident that their "simple and highly effective method will soon be installed in the existing and upcoming HS-AFM systems, and will improve a wide range of HS-AFM imaging studies in biophysics and other fields."

Related images

https://nanolsi.kanazawa-u.ac.jp/wp-content/uploads/2021/03/Fig-1Ando.jpg

Caption for Figure 1: Difference of invasiveness between trace and retrace scanning processes.

(a) Raster scanning: Trace scanning (red line) and retrace scanning (blue line) of the sample stage,

(b) directions of tip scanning relative to sample in trace and retrace scanning processes,

(c) difference in feedback control error between the trace and retrace scanning processes. Error images of the actin filament oriented nearly along the Y-axis (top) and the error profile (bottom),

(d, e) difference in the directions of torques produced by lateral and vertical forces exerted on the cantilever from the sample during trace (d) and retrace (e) scanning processes,

(f, g) HS-AFM images of actin filaments captured at 10 fps in the OTI (f) and ORI (g) modes. In the ORI mode, actin filaments were quickly broken.

https://nanolsi.kanazawa-u.ac.jp/wp-content/uploads/2021/03/Fig-2Ando.jpg

Figure 2. The circuit installed for the OTI mode and its operation.

(a) During retrace scanning, a DC offset signal (Aos < 0) is added to the amplitude signal (A). The feedback control operates as if the probe were in strong contact with the sample, and thus the sample stage is moved away from the tip.

(b) Driving signal for X-scanner in the OTI mode (top), DC offset signal added to true amplitude signal (middle), and Z-scanner displacement (bottom).

Reference

Shingo Fukuda and Toshio Ando. Faster high-speed atomic force microscopy for imaging of biomolecular processes, Rev. Sci. Instrum.92, 033705 (2021).

DOI: 10.1063/5.0032948
URL: https://aip.scitation.org/doi/10.1063/5.0032948

About WPI nanoLSI Kanazawa University

Hiroe Yoneda
Vice Director of Public Affairs
WPI Nano Life Science Institute (WPI-NanoLSI)
Kanazawa University
Kakuma-machi, Kanazawa 920-1192, Japan
Email: nanolsi-office@adm.kanazawa-u.ac.jp
Tel: +81 (76) 234-4550

About Nano Life Science Institute (WPI-NanoLSI)
https://nanolsi.kanazawa-u.ac.jp/en/

Nano Life Science Institute (NanoLSI), Kanazawa University is a research center established in 2017 as part of the World Premier International Research Center Initiative of the Ministry of Education, Culture, Sports, Science and Technology. The objective of this initiative is to form world-tier research centers. NanoLSI combines the foremost knowledge of bio-scanning probe microscopy to establish 'nano-endoscopic techniques' to directly image, analyze, and manipulate biomolecules for insights into mechanisms governing life phenomena such as diseases.

About Kanazawa University
http://www.kanazawa-u.ac.jp/e/

As the leading comprehensive university on the Sea of Japan coast, Kanazawa University has contributed greatly to higher education and academic research in Japan since it was founded in 1949. The University has three colleges and 17 schools offering courses in subjects that include medicine, computer engineering, and humanities.

The University is located on the coast of the Sea of Japan in Kanazawa - a city rich in history and culture. The city of Kanazawa has a highly respected intellectual profile since the time of the fiefdom (1598-1867). Kanazawa University is divided into two main campuses: Kakuma and Takaramachi for its approximately 10,200 students including 600 from overseas.

KI-Champions: 3 Top-Werte, die Ihr Portfolio revolutionieren
Fordern Sie jetzt den brandneuen kostenfreien Sonderreport an und erfahren Sie, wie Sie von den enormen Wachstumschancen im Bereich Künstliche Intelligenz profitieren können - 100 % kostenlos.
Hier klicken
© 2021 PR Newswire
Werbehinweise: Die Billigung des Basisprospekts durch die BaFin ist nicht als ihre Befürwortung der angebotenen Wertpapiere zu verstehen. Wir empfehlen Interessenten und potenziellen Anlegern den Basisprospekt und die Endgültigen Bedingungen zu lesen, bevor sie eine Anlageentscheidung treffen, um sich möglichst umfassend zu informieren, insbesondere über die potenziellen Risiken und Chancen des Wertpapiers. Sie sind im Begriff, ein Produkt zu erwerben, das nicht einfach ist und schwer zu verstehen sein kann.